Size
2100mm
Brand
Keystone

Downloads

There are no download types with downloads for this product.

Reviews

There are currently no reviews, be the first to review.

Leave us your review

You need to login to submit a review. Please click here to log in or register .

Bulk pricing

0 +
£82.33 excl VAT

Stock Enquiry Form

Keystone Lintel EL/K-90 2100mm
Keystone Lintel EL/K-90 2100mm
0103217

Please enter a valid Email AddressPlease enter a valid Email AddressThe Email Address entered is already registered, please sign in with the Email Address or enter a different one

Please enter a name

Please confirm you are not a robot.
We have been unable to verify your identity, please confirm you are not a robot.

Keystone Lintel EL/K-90 2100mm

0103217
£98.80 incl VAT (£82.33 excl VAT)
Each
Out Of Stock

Product information

EL/K-90

Inner Leaf 100mm

EL/K lintels are designed to provide support over openings at eaves level. The eaves lintel has a shortened outer flange to allow the underside of the soffit board to be positioned tight against the window frame. It must be noted that brickwork cannot be built onto the outer flange of an eaves lintels. Masonry is built on the inner leaf only.

 

Length

(mm)

Height

(mm)

Thickness

(mm)

Total UDL

kN 19:1

600 - 1500

1061.818

1650 - 2100

1442.020

2250 - 2400

1632.022

2550 - 2700

1642.5

25

 

The loading figures are achieved by considering the lintel and masonry as a composite unit.

The lintel must have a minimum end bearing of 150mm on each side of the opening bedded on mortar. Level the lintel along its length and across its width. The lintel must be positioned to ensure that the masonry is built against the vertical upstand of the lintel. Masonry should be bedded on mortar and all perpendicular joints filled with mortar.

A continuous timber wall plate must extend along the masonry immediately above the lintel. Lintel may be propped to facilitate speed of construction. A plaster key is incorporated into the inner leaf of the lintel.

The Keystone Eaves lintel also incorporates a thermal break plate on the underside of the lintel for superior structural performance.